American Standard SELECTRONIC 6065.565 Manuale Utente

Navigare online o scaricare Manuale Utente per Prodotti sanitari American Standard SELECTRONIC 6065.565. Installation Instructions - American Standard ProSite Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
Installation Instructions
Installation Instructions
Certified to comply with ASME A112.19.2
© 2014 AS America, Inc.
Exposed Flushometer
for 1-1/2" Top Spud Bowls
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.
M965646 REV. 1.2 (4/15)
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
DC POWERED PROXIMITY EXPOSED
TOILET FLUSH VALVE
1.1, 1.28, 1.6,
1.6 / 1.1, & 1.28/1.1 GPF
SELECTRONIC
®
6065.111
6065.121
6065.161
6065.721
6065.761
6065.521
6065.525
6065.561
6065.565
6066.111
6066.121
6066.161
6066.721
6066.761
MODEL NUMBERS
NOTE TO INSTALLER: Please give this manual to the customer after installation.NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic
®
Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
Vedere la pagina 0
1 2 3 4 5 6 7 8 9

Sommario

Pagina 1 - Installation Instructions

Installation InstructionsInstallation InstructionsCertified to comply with ASME A112.19.2© 2014 AS America, Inc.Exposed Flushometerfor 1-1/2" Top

Pagina 2 - UNPACKING

5. Spud Flange 6. Wall Escutcheon7. Cover Tube8. Sweat Adapter9. Stop Valve1. Installation Instructions2. Flush Valve Body Assembly3. Vacuum Breaker T

Pagina 3 - PRIOR TO INSTALLATION

RECOMMENDED TOOLS; Fig. 2Fig. 21.2.3.4.5.6.7.8.9.10.Teflon Tape Flat Blade ScrewdriverAdjustable Wrench Tape Measure HacksawTubing CutterFileFor Swe

Pagina 4 - FLUSH VALVE INSTALLATION

3M965646 REV. 1.2 (4/15)12345Fig. 51-1/2" TOP SPUD11423Fig. 41. Measure from finished wall to first thread of Adapter or threaded supply pip

Pagina 5 - INSTALLATION; Fig. 7

4M965646 REV. 1.2 (4/15)3. Pull the VACUUM BREAKER TUBE (7) up to meet thethreaded FLUSH VALVE BODY (5), hand tighten the VACUUM BREAKER COUPLING NUT

Pagina 6 - MAINTENANCE

5M965646 REV. 1.2 (4/15)1Fig. 92REMOVE COVERCLOCKWISE CLOSESSTOP VALVECOUNTER-CLOCKWISEOPENS STOP VALVEIMPORTANT: To avoid overflowing, the STOP VALVE

Pagina 7 - PACK; Fig. 11, 11b

6M965646 REV. 1.2 (4/15)3348 REPLACE BATTERY; Fig. 11, 11a3C1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of FLUSH VALVE COVER (3). F

Pagina 8 - SET DETECTION RANGE

7M965646 REV. 1.2 (4/15)111" - 2" (30mm - 50mmBLINKING LEDBLINKING LEDFig. 14DETECTION ZONE400mm TO 800mm(Factory Setting: 400mm) SET DE

Pagina 9 - TROUBLESHOOTING FLOW CHARTS

8M965646 REV. 1.2 (4/15)TROUBLESHOOTING FLOW CHARTSNNOO YYEESS NNOO YYEESS NNOO 11 22 11 22YYEESS NNOO YYEESS NNOO UNIT DOES NOT FUNCTION

Commenti su questo manuale

Nessun commento